CN
    Input signal
    Output signal
    Channels
    Power Supply Mode
    The following 35 products are eligible
    NPEXA-C01H
    1 input and 1 output contrast
    Temperature input isolated barrier, it converts the thermocouple/thermal resistance signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has external cold junction compensation terminals. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.
    NPEXA-C011H
    1 input and 2 outputs contrast
    Temperature input isolated barrier, it converts the thermocouple/thermal resistance signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has external cold junction compensation terminals. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.nt power supply.
    NPEXA-C0D11
    2 inputs and 2 outputs contrast
    Temperature input isolated barrier, it converts the thermocouple/thermal resistance signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has external cold junction compensation terminals. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.ation terminals. It needs an independent power supply.
    NPEXA-C11H
    1 input and 1 output contrast
    Temperature input isolated barrier, it converts the thermocouple signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has external cold junction compensation terminals. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.
    NPEXA-C111H
    1 input and 2 outputs contrast
    Temperature input isolated barrier, it converts the thermocouple signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has external cold junction compensation terminals. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.It has external cold junction compensation terminals. It needs an independent power supply. The input, output,
    NPEXA-C1D11
    2 inputs and 2 outputs contrast
    Temperature input isolated barrier, it converts the thermocouple signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has external cold junction compensation terminals. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.